MODULAR EEG SYSTEM — DEYMED
TruScan™ EEG
A professional EEG system developed by Deymed Diagnostic — battery-powered amplifiers with optical isolation for maximum signal quality, a modular design with 5 headbox variants (24 to 288 channels) and 4 configurations (Flexicart, ICU Cart, Portable, NeuroTablet). Indicated for routine EEG, prolonged ICU monitoring, Holter EEG, sleep medicine and neurophysiology research.
Model: Deymed TruScan EEG
CONCEPT
"Battery-first" + optical isolation = clean EEG signal
Unlike classic mains-powered EEG systems, TruScan runs exclusively on battery with full optical isolation from the operating cart. This eliminates electrical artifacts (50 Hz / 60 Hz hum, EMI) and dramatically reduces digital signal cleaning — the difference is clinically visible, especially in long recordings in the ICU and sleep medicine.
- 100% battery-powered amplifiers — no ground loops, no 50 Hz
- Optical cable electrically isolates the patient from the cart
- Smart inductive charging — keeps the isolation in the cart
- Hot-swap battery — change the battery without stopping the recording
- Wireless 100 m standard, extensible to 300 m
- Click N' Go — detach the headbox from the cart in one click for portable use
AVAILABLE HEADBOXES
5 models — for any clinical scenario
TruScan comes with five headbox variants, each suited to a specific clinical scenario — from routine EEG to research with hundreds of channels.
ROUTINE
TruScan LT — 24 / 32 canale
Compact headbox for routine EEG in outpatient settings and the practice. AC amplifier, sampling up to 6,000 Hz. Optional wireless for portable use. Canon25 connector.
- 24 or 32 AC channels
- Sampling up to 6,000 Hz
- Optional wireless
- Low cost — ideal for a neurology practice
HOLTER EEG
TruScan RS — 32 canale
Optimised for ambulatory Holter-EEG recording. Wireless included as standard, lightweight design for prolonged wear. AC amplifier.
- 32 AC channels
- Wireless included, 25–45h battery life
- Design for ambulatory wear
- Auto-sync data on return to range
CLINIC / ATI
TruScan LT Plus — 32 / 72 / 144 / 288 canale
Clinical flagship — DC, 16 kHz sampling, scalable from 32 to 288 channels (dual / quad 72). Impedance LEDs on the headbox, integrated accelerometer and light sensor. Ideal for the ICU and complex epilepsy.
- 32–288 DC channels (single, dual, quad-72)
- Sampling up to 16,000 Hz
- Impedance LEDs on the headbox
- Integrated accelerometer + light sensor
TMS COMPATIBIL
TruScan RE Plus — 32 / 72 / 144 / 288 canale
RESEARCH variant with TMS compatibility — allows recording immediately after the TMS pulse without damaging the amplifier. Used in advanced neurophysiology research (combined TMS-EEG).
- Compatible with TMS pulses
- 32 to 288 DC channels
- 16 kHz sampling, short post-TMS recovery window
- Indicated for research with DuoMAG TMS
INCLUDED SOFTWARE
Complete acquisition + review + ICU suite
ACQUISITION
TruScan EEG Acquisition
A dashboard-style interface with real-time impedance, preset markers for stimulation events, custom drag-and-drop montages. Look-back review during acquisition, visual alarms for out-of-range electrodes.
- "Always On" impedance with alerts
- Preset text markers
- Custom drag-and-drop montages
- Look-back review during recording
REVIEW
TruScan EEG Explorer
Review software with an interpretation editor, a patient database with a "To-Do" list for un-interpreted EEGs, full-text search. Spectral analysis, brain mapping, custom reports with preset templates. EEG export with an included viewer (flash drive).
- Interpretation editor with preset text
- Patient database with a "To-Do" list
- Spectral analysis + brain mapping
- EEG export + viewer on a flash drive
ATI
ICU mode — touchscreen-optimised
An interface specially designed for intensive care — video preview + impedance, landscape or portrait orientation, touch navigation. Essential for continuous EEG monitoring in neurosurgery, post-cardiac arrest, status epilepticus.
- Touchscreen-optimised interface
- Combined video preview + impedance
- Landscape / portrait orientation
- Indicated for prolonged ICU monitoring
CONTROLLER
EEG Explorer Keyboard
A dedicated multifunction keyboard, user-programmable. It reduces mouse dependence with dedicated review controls (large jog wheel, marker buttons, epoch navigation). It dramatically increases interpretation speed.
- User-programmable
- Large jog wheel for navigation
- Dedicated buttons for markers
- Speeds up interpretation by 30–50%
AVAILABLE CONFIGURATIONS
4 forms — practice, ICU, transport, ambulatory
FLEXICART
Integrated cart with PC + flexible arm
An all-in-one configuration with an integrated silent PC (fanless, passive cooling), flexible monitor arm, photic lamp, headbox extender, optional video system. For the neurology practice and clinic.
ICU CART
Intensive-care configuration
An enhanced cart for ICU manoeuvrability, with tablet / NeuroTablet / PC options. PTZ cameras for video-EEG synchronisation, IR lamp for night-time. Indicated for prolonged monitoring in neurosurgery and status epilepticus.
PORTABIL
Portable USB system
A compact setup for travel — USB adapter with a headbox connector, optional FlexiTrolley. Useful for bedside consults in wards without a dedicated EEG, or for internal transport.
NEUROTABLET
Tablet for rapid transport
An all-in-tablet solution for rapid bedside deployment. Wireless headbox + touch tablet — no cart, no cables. Essential for space-constrained ICUs.
TECHNICAL SPECIFICATIONS
TruScan EEG operating parameters
| Headbox models | 5 variants: LT, RS, LT Plus, RS Plus, RE Plus |
|---|---|
| Channels | 24 – 288 (depending on model) |
| Rată eșantionare | Up to 6,000 Hz (AC, LT/RS) · 16,000 Hz (DC, Plus) |
| Amplifier type | AC (LT, RS) · DC (LT Plus, RS Plus, RE Plus) |
| Isolation | Full optical — optical cable to the cart |
| Power supply | Integrated battery (Li-ion) — inductive charging |
| Battery life (optical) | 50 – 96 hours (depending on model + channels) |
| Battery life (wireless) | 25 – 45 hours |
| Wireless range | 100 m standard · 300 m optional |
| Connectors | Canon25, touch-proof, DEYMED 3-pin (high-channel) |
| Network / IT | HL7 integration, isolated gigabit network connection |
| Impedance monitoring | "Always On" — real-time, with alerts + values saved to file |
| Hot-swap battery | Yes — change without interrupting the recording |
| Integrated sensors | Accelerometer + light sensor (Plus, RE) |
| TMS compatibility | RE Plus — recording immediately after the TMS pulse |
| Manufacturer | DEYMED Diagnostic (Czech Republic) |
CLINICAL INDICATIONS
Where TruScan makes the difference
-
Routine ambulatory EEG
Neurology practice — TruScan LT/RS with 24–32 channels. Recording, hyperventilation, photic stimulation, daytime sleep.
-
Continuous ICU EEG monitoring
Post-cardiac arrest, status epilepticus, severe stroke, encephalitis — ICU mode + cart with PTZ cameras for video-EEG.
-
Ambulatory Holter EEG
24h+ recording with TruScan RS / RS Plus. Wireless data auto-sync. For detecting rare or partial seizures.
-
Complex epilepsy
Plus variants (72–288 channels) for pre-surgical epilepsy evaluation. Video synchronisation, custom markers, brain mapping.
-
Sleep medicine & PSG
Polysomnography with extended channels — integration with SomniPro PSG (separate module) for complete sleep studies.
-
Neurophysiology research
TruScan RE Plus — compatible with DuoMAG TMS for combined TMS-EEG studies. 16 kHz sampling for high-resolution research.
WHY THE TruScan EEG
The EEG system with the fewest artifacts in its class
All EEGs detect brainwaves. The difference between an average one and TruScan is the background noise — TruScan, through "battery-first" + optical isolation, delivers a clean signal that no longer needs digital filtering. In practice: clearer epileptic markers, fewer myoclonic artifacts, faster interpretation.
- Built in the Czech Republic — DEYMED Diagnostic, founded 1991
- Battery-first design, unique on the market
- The only EEG platform with a TMS-compatible RE Plus
- Modular — the same software for practice and research
- Ecosystem integration: TruTrace EMG + DuoMAG TMS
Interested in the TruScan EEG?
Hellimed provides technical consulting, clinical demonstrations, installation and training for the TruScan EEG — for neurology practices, ICUs, neurosurgery departments, sleep laboratories and research centres. Tell us which configuration you need (LT for the practice, ICU Cart for the ICU, RS for Holter, RE Plus for TMS-EEG research).
Request a quote for the TruScan EEG