LOW-TEMPERATURE STERILIZATION — STERIS

Hydrogen peroxide sterilizer STERIS V-PRO S2

Small-capacity vaporized hydrogen peroxide sterilizer STERIS V-PRO S2. Low-temperature sterilization for heat-sensitive instruments — rigid endoscopes, cables, lumened instruments.

Model: STERIS V-PRO S2

Hydrogen peroxide sterilizer STERIS V-PRO S2
45 L chamber capacity
28-55 min cycle time
50°C max temperature
6-log spore validation

DESCRIPTION

About the product

The STERIS V-PRO S2 is the compact solution for low-temperature sterilization of heat- and moisture-sensitive instruments. It uses VHP™ (Vaporized Hydrogen Peroxide) technology — hydrogen peroxide vaporized in fast-cycle chambers that leaves instruments ready to use with no toxic residue and no aeration time.

The small chamber (~45 L) makes the V-PRO S2 ideal for specialty practices with moderate instrument volume — ENT, ophthalmology, invasive cardiology, gastroenterology, urology. It handles rigid endoscopes, long thin lumened instruments (down to 1 mm diameter × 850 mm length), electrical cables, polymer and composite instruments. Typical cycle 28–55 minutes, fully automated, with 6-log validation.

Manufacturer page →

Hydrogen peroxide sterilizer STERIS V-PRO S2

VIDEO DEMO

Hydrogen peroxide sterilizer STERIS V-PRO S2 in action

KEY FEATURES

What it does

  • 45 L chamber — ideal for specialty practices
  • 28-55 min cycle, no aeration time
  • 6-log validation against standard spores
  • Lumened instruments (≥1 mm × ≤850 mm)
  • Rigid endoscopes, cables, polymers
  • Touchscreen + STERIS Connect™
  • Compliance ISO 14937, EN 14937
  • Manufacturer: STERIS Healthcare

SPECIFICATIONS

Technical specifications

Type Vaporized hydrogen peroxide (VHP™) sterilizer, small capacity
Chamber ~45 L
Material Stainless steel
Max temperature ~50°C (low temperature)
Sterilant Vaporized H₂O₂
Lumen accepted Ø ≥ 1 mm × L ≤ 850 mm
Cycle 28-55 min (program dependent)
Compliance ISO 14937, EN 14937, 6-log validation
Manufacturer STERIS Healthcare

APPLICATIONS

Where it is used

  • ENT practice

    Rigid endoscope and delicate instrument sterilization.

  • Ophthalmology

    Heat-sensitive microsurgical instruments.

  • Invasive cardiology

    Electrical cables, lumened instruments.

  • Gastroenterology

    Rigid endoscopes, polymer accessories.

  • Urology

    Rigid cystoscopes, specific instruments.

  • Moderate-volume CSSD

    EtO alternative for sensitive materials.

Interested in this product?

Hellimed provides technical consulting, demonstrations, installation and service for the full STERIS and SMEG sterilization portfolio. Tell us your capacity and application and we will recommend the optimal configuration.

Request a quote