TRANSCRANIAL MAGNETIC STIMULATOR (rTMS) — DEYMED

DuoMAG XT / XTR

A biphasic repetitive transcranial magnetic stimulator (rTMS) from Deymed Diagnostic — for clinical use and neurophysiology research. 3 power variants (XT-10 / XT-35 / XT-100) plus the XTR model (theta-burst at 100% intensity). 15+ compatible coils (butterfly, round, T-shaped, V-shaped, liquid-cooled). Native integration with TruScan EEG and TruTrace EMG on the same cart.

Model: XT-10 / XT-35 / XT-100 / XTR

Deymed DuoMAG XT / XTR transcranial magnetic stimulator (rTMS)
100 ppsmaximum rate (XT-100 / XTR)
15+compatible coils
4models (XT-10 / 35 / 100 / XTR)
TBStheta-burst at 100% (XTR)

CONCEPT

Biphasic rTMS for the entire therapeutic and research spectrum

TMS (Transcranial Magnetic Stimulation) induces weak electrical currents in the brain via rapidly changing magnetic fields generated by a coil placed on the scalp. At high frequencies ("rTMS"), the technique modulates cortical excitability — used therapeutically in resistant depression, OCD, chronic pain, post-stroke recovery, and as a central tool in neurophysiology research (TMS-EEG, TMS-EMG with MEP).

DuoMAG XT uses biphasic pulses — the most energy-efficient option for sustained repetitive protocols. The XTR model adds the unique ability to deliver theta-burst (TBS) protocols at 100% intensity — essential for advanced clinical research.

  • Biphasic pulses — efficient for sustained rTMS
  • 3 power variants: XT-10 (30 pps), XT-35 (60 pps), XT-100 (100 pps)
  • XTR — theta-burst at 100% intensity, premium research
  • Windows touchscreen + programmable custom protocols
  • MagTower — counterbalanced arm for effortless positioning
  • TTL In/Out + USB synchronisation with external systems (EEG / EMG)
DuoMAG XTR cu MagTower

AVAILABLE MODELS

4 variants — from clinical rTMS to TBS research

XT-10XT-35XT-100XTR
Pulse typeBiphasicBiphasicBiphasicBiphasic
ModeSingle, RepetitiveSingle, Rep, BurstSingle, Rep, BurstSingle, Rep, Burst
Max repetition rate30 pps60 pps100 pps100 pps
TBS @ 100%Yes
Target useStandard clinicalClinical + researchIntensive clinical + researchPremium research, TBS
SynchronisationTTL In/Out + USB · Control on Coil
Power supply100–240 VAC, 50/60 Hz
Coil compatibilityAll DEYMED coils — 15+ models

COMPATIBLE COILS

15+ models — butterfly, round, T-shaped, V-shaped

Different shapes and sizes to deliver a focused or distributed, superficial or deep magnetic field. Liquid-cooled (LQC) variants for intensive all-day protocols without overheating.

70BF butterfly coil

BUTTERFLY

Butterfly coils (Figure-8)

The most used type in the clinic. A magnetic field focused at the crossing point of the two coils — ~2.5 cm penetration, ideal for the motor cortex and DLPFC.

  • 30BF, 50BF, 70BF — different focusing
  • Air-cooled (Cool) or liquid-cooled (LQC) variants
  • Placebo (P) variants for sham-controlled studies
  • The most popular: 70BF-LQC for clinical rTMS
70HF T-shaped

T-SHAPED

T-shaped coils for TBS

Built specifically for high-intensity theta-burst protocols. Liquid cooling mandatory for TBS at 100% intensity. Combined with the XTR model.

  • 30BFT, 50BFT, 70HF-LQC
  • Maximum heat dissipation with LQC
  • Optimal for iTBS / cTBS
  • Combined with XTR for standard Cole et al. protocols
90BFVT V-shaped

V-SHAPED

V-shaped coils for deep stimulation

Anatomical conformance to the scalp — deeper magnetic-field penetration. 90BFVT-LQC at 120° for the extended prefrontal cortex, 120BFVT for deep stimulation.

  • 90BFVT-LQC — 120° angle, liquid cooling
  • 120BFVT — deep penetration
  • Indicated dTMS-like (off-label, distributes over a wider area)
  • Used in DLPFC / orbital-cortex studies
100R round coil

ROUND

Round coils for a distributed field

A less focused magnetic field, distributed over a wider area. Indicated for MEP screening, initial cortical mapping, and applications that do not require strict focusing.

  • 100R and 125R — different sizes
  • Distributed field, low-focus
  • Indicated for rapid MEP screening
  • Compatible with all XT / XTR models

AVAILABLE CONFIGURATIONS

3 forms — MagTower / MagCart / Compact

MagTower

MAGTOWER

Counterbalanced arm with auto-lock

The premium solution for the rTMS practice — a counterbalanced arm that reduces positioning effort to zero, auto-lock in position, integrated touchscreen, optional support for a cooling system and an EMG headbox for MEP.

  • Counterbalanced arm — no positioning effort
  • Auto-lock at any angle
  • Integrated touchscreen
  • Optional mount for liquid cooling + EMG headbox
MagCart

MAGCART

Compact mobile cart

A mobile cart for use across multiple rooms or in limited space. Optional articulated arm, laptop / touchscreen support, accommodation for a cooling system.

  • Wheeled cart for moving between rooms
  • Optional articulated arm
  • Laptop or touchscreen support
  • Compatible with the liquid-cooling system
Compact

COMPACT

Desktop configuration

The most affordable variant — a desktop stimulator without an integrated arm. The operator holds the coil manually. Indicated for research with short sessions and limited space. NOT compatible with liquid cooling.

  • On the desk — the most compact variant
  • Coil held manually by the operator
  • Indicated for short research, mapping
  • No liquid cooling — limited sessions
TMS Chair

SCAUN rTMS

Electrically adjustable rTMS chair

A chair designed for the rTMS practice — electric adjustment of the backrest, height and tilt. Optional headrest support for head immobilisation. Essential for repeated therapeutic sessions.

  • Electric height + backrest + tilt adjustment
  • Optional headrest for head immobilisation
  • Standard for therapeutic rTMS practices
  • Reproducible patient positioning

KEY ACCESSORIES

Cooling + EMG integration + control

Liquid Cooling

LIQUID COOLING

Liquid-cooling system for LQC coils

Allows intensive all-day use without overheating — essential for a therapeutic rTMS practice with 6–8 patients per day or research with TBS protocols at 100%.

  • Continuous cooling for LQC coils
  • Unlimited sessions with no cooling breaks
  • Essential for TBS at 100% (XTR)
  • Visual cooling-status indicator
TruTrace EMG TMS-compatible

INTEGRARE EMG

TMS-compatible TruTrace headbox

A 2ch or 4ch headbox from the TruTrace EMG family, TMS-compatible — it records MEP immediately after the TMS pulse without damaging the amplifier. Controlled directly from the DuoMAG software.

  • TruTrace 2ch or 4ch — TMS-compatible
  • MEP recording immediately after the pulse
  • Direct control from the DuoMAG software
  • For motor-cortex mapping, MT (motor threshold)
DuoMAG software

SOFTWARE

Windows interface + dashboard

Touchscreen software for complete control — preset protocols (10 Hz, iTBS, cTBS, deep TMS), a custom-protocol creator, patient database, automatic per-session report, user management with access rights.

  • Preset protocols (10 Hz, iTBS, cTBS)
  • Custom protocol creator
  • Patient database + per-session report
  • User management + access rights
Control on Coil

CONTROL ON COIL

Control buttons on the coil

Physical buttons on the coil handle for intensity adjustment / start-stop / marker — the operator does not need to return to the console during the session.

  • Start / Stop directly on the coil
  • Intensity adjustment on the handle
  • Programmable event marker
  • Reduces session interruption

TECHNICAL SPECIFICATIONS

DuoMAG XT / XTR operating parameters

Models4 variants: XT-10, XT-35, XT-100, XTR
Pulse typeBiphasic (all 4 models)
Max repetition rate30 / 60 / 100 / 100 pps (XT-10 / XT-35 / XT-100 / XTR)
ModesSingle · Repetitive · Burst (Burst only on XT-35 / XT-100 / XTR)
Theta-Burst @ 100%XTR — exclusive
Compatible coils15+ DEYMED models (butterfly, T-shaped, V-shaped, round)
Coil coolingAir (Cool) or liquid (LQC) — optional on MagTower / MagCart
SynchronisationTTL In/Out + USB Full Control · Control on Coil
SoftwareWindows touchscreen · preset + custom protocols · per-session report
IntegrareTruScan EEG (TMS-EEG) · TruTrace EMG (MEP)
ConfigurationsMagTower (counterbalanced arm) · MagCart (mobile) · Compact (desktop)
Power supply100–240 VAC, 50/60 Hz
ManufacturerDEYMED Diagnostic (Czech Republic)
ComplianceMarcaj CE (MDR)

CLINICAL & RESEARCH INDICATIONS

Where the DuoMAG XT makes the difference

  • Treatment-resistant depression

    10 Hz rTMS protocols over the left DLPFC — therapy approved by FDA / CE for MDD. With XTR + iTBS, a 3-minute protocol (Cole et al. 2018).

  • Obsessive-compulsive disorder (OCD)

    Deep TMS stimulation over the SMA / medial prefrontal cortex — V-shaped 90BFVT or 120BFVT coils for deep penetration.

  • Post-stroke recovery

    rTMS for motor and aphasia rehabilitation after stroke — low-frequency protocols on the healthy hemisphere or high-frequency on the lesioned cortex.

  • Chronic pain (fibromyalgia, neuropathy)

    rTMS over the M1 motor cortex for refractory chronic pain — 10 Hz protocols with 70BF-LQC, indicated in international guidelines.

  • Motor-cortex mapping (MEP)

    With TMS-compatible TruTrace EMG — pre-surgical or research mapping, MT (motor threshold) calculation, screening with a 100R/125R round coil.

  • TMS-EEG / TMS-EMG research

    With TruScan EEG (RE Plus, TMS-compatible) or TruTrace EMG — advanced studies of cortical excitability, SICI, LICI, synaptic plasticity (TBS).

WHY THE DuoMAG XT

One of the few rTMS devices with TBS at 100% intensity (XTR)

The most recent FDA-approved rTMS protocols (SAINT, Stanford 2022) use iTBS at 100% intensity. Very few rTMS devices on the market can deliver this protocol — XTR is one of them. Plus, the native integration with Deymed EEG / EMG / IONM makes DuoMAG the ideal solution for research centres + ambulatory TMS clinics.

  • XTR — TBS at 100% intensity (rare on the market)
  • 15+ compatible coils, including liquid cooling
  • TruScan EEG + TruTrace EMG integration on the same cart
  • Built in the Czech Republic — DEYMED Diagnostic (founded 1991)
  • CE marked MDR · European technical support

Interested in the DuoMAG XT / XTR?

Hellimed provides technical consulting, clinical demonstrations, installation and training for the DuoMAG XT — for therapeutic rTMS practices (depression, OCD), neuro-rehabilitation departments and neurophysiology research laboratories (TMS-EEG, TMS-EMG). Tell us which variant you need (XT-10 / XT-35 / XT-100 for clinical use, XTR for premium research with TBS).

Request a quote for the DuoMAG XT