TRANSCRANIAL MAGNETIC STIMULATOR (rTMS) — DEYMED
DuoMAG™ XT / XTR
A biphasic repetitive transcranial magnetic stimulator (rTMS) from Deymed Diagnostic — for clinical use and neurophysiology research. 3 power variants (XT-10 / XT-35 / XT-100) plus the XTR model (theta-burst at 100% intensity). 15+ compatible coils (butterfly, round, T-shaped, V-shaped, liquid-cooled). Native integration with TruScan EEG and TruTrace EMG on the same cart.
Model: XT-10 / XT-35 / XT-100 / XTR
CONCEPT
Biphasic rTMS for the entire therapeutic and research spectrum
TMS (Transcranial Magnetic Stimulation) induces weak electrical currents in the brain via rapidly changing magnetic fields generated by a coil placed on the scalp. At high frequencies ("rTMS"), the technique modulates cortical excitability — used therapeutically in resistant depression, OCD, chronic pain, post-stroke recovery, and as a central tool in neurophysiology research (TMS-EEG, TMS-EMG with MEP).
DuoMAG XT uses biphasic pulses — the most energy-efficient option for sustained repetitive protocols. The XTR model adds the unique ability to deliver theta-burst (TBS) protocols at 100% intensity — essential for advanced clinical research.
- Biphasic pulses — efficient for sustained rTMS
- 3 power variants: XT-10 (30 pps), XT-35 (60 pps), XT-100 (100 pps)
- XTR — theta-burst at 100% intensity, premium research
- Windows touchscreen + programmable custom protocols
- MagTower — counterbalanced arm for effortless positioning
- TTL In/Out + USB synchronisation with external systems (EEG / EMG)
AVAILABLE MODELS
4 variants — from clinical rTMS to TBS research
| XT-10 | XT-35 | XT-100 | XTR | |
|---|---|---|---|---|
| Pulse type | Biphasic | Biphasic | Biphasic | Biphasic |
| Mode | Single, Repetitive | Single, Rep, Burst | Single, Rep, Burst | Single, Rep, Burst |
| Max repetition rate | 30 pps | 60 pps | 100 pps | 100 pps |
| TBS @ 100% | — | — | — | Yes |
| Target use | Standard clinical | Clinical + research | Intensive clinical + research | Premium research, TBS |
| Synchronisation | TTL In/Out + USB · Control on Coil | |||
| Power supply | 100–240 VAC, 50/60 Hz | |||
| Coil compatibility | All DEYMED coils — 15+ models | |||
COMPATIBLE COILS
15+ models — butterfly, round, T-shaped, V-shaped
Different shapes and sizes to deliver a focused or distributed, superficial or deep magnetic field. Liquid-cooled (LQC) variants for intensive all-day protocols without overheating.
BUTTERFLY
Butterfly coils (Figure-8)
The most used type in the clinic. A magnetic field focused at the crossing point of the two coils — ~2.5 cm penetration, ideal for the motor cortex and DLPFC.
- 30BF, 50BF, 70BF — different focusing
- Air-cooled (Cool) or liquid-cooled (LQC) variants
- Placebo (P) variants for sham-controlled studies
- The most popular: 70BF-LQC for clinical rTMS
T-SHAPED
T-shaped coils for TBS
Built specifically for high-intensity theta-burst protocols. Liquid cooling mandatory for TBS at 100% intensity. Combined with the XTR model.
- 30BFT, 50BFT, 70HF-LQC
- Maximum heat dissipation with LQC
- Optimal for iTBS / cTBS
- Combined with XTR for standard Cole et al. protocols
V-SHAPED
V-shaped coils for deep stimulation
Anatomical conformance to the scalp — deeper magnetic-field penetration. 90BFVT-LQC at 120° for the extended prefrontal cortex, 120BFVT for deep stimulation.
- 90BFVT-LQC — 120° angle, liquid cooling
- 120BFVT — deep penetration
- Indicated dTMS-like (off-label, distributes over a wider area)
- Used in DLPFC / orbital-cortex studies
ROUND
Round coils for a distributed field
A less focused magnetic field, distributed over a wider area. Indicated for MEP screening, initial cortical mapping, and applications that do not require strict focusing.
- 100R and 125R — different sizes
- Distributed field, low-focus
- Indicated for rapid MEP screening
- Compatible with all XT / XTR models
AVAILABLE CONFIGURATIONS
3 forms — MagTower / MagCart / Compact
MAGTOWER
Counterbalanced arm with auto-lock
The premium solution for the rTMS practice — a counterbalanced arm that reduces positioning effort to zero, auto-lock in position, integrated touchscreen, optional support for a cooling system and an EMG headbox for MEP.
- Counterbalanced arm — no positioning effort
- Auto-lock at any angle
- Integrated touchscreen
- Optional mount for liquid cooling + EMG headbox
MAGCART
Compact mobile cart
A mobile cart for use across multiple rooms or in limited space. Optional articulated arm, laptop / touchscreen support, accommodation for a cooling system.
- Wheeled cart for moving between rooms
- Optional articulated arm
- Laptop or touchscreen support
- Compatible with the liquid-cooling system
COMPACT
Desktop configuration
The most affordable variant — a desktop stimulator without an integrated arm. The operator holds the coil manually. Indicated for research with short sessions and limited space. NOT compatible with liquid cooling.
- On the desk — the most compact variant
- Coil held manually by the operator
- Indicated for short research, mapping
- No liquid cooling — limited sessions
SCAUN rTMS
Electrically adjustable rTMS chair
A chair designed for the rTMS practice — electric adjustment of the backrest, height and tilt. Optional headrest support for head immobilisation. Essential for repeated therapeutic sessions.
- Electric height + backrest + tilt adjustment
- Optional headrest for head immobilisation
- Standard for therapeutic rTMS practices
- Reproducible patient positioning
KEY ACCESSORIES
Cooling + EMG integration + control
LIQUID COOLING
Liquid-cooling system for LQC coils
Allows intensive all-day use without overheating — essential for a therapeutic rTMS practice with 6–8 patients per day or research with TBS protocols at 100%.
- Continuous cooling for LQC coils
- Unlimited sessions with no cooling breaks
- Essential for TBS at 100% (XTR)
- Visual cooling-status indicator
INTEGRARE EMG
TMS-compatible TruTrace headbox
A 2ch or 4ch headbox from the TruTrace EMG family, TMS-compatible — it records MEP immediately after the TMS pulse without damaging the amplifier. Controlled directly from the DuoMAG software.
- TruTrace 2ch or 4ch — TMS-compatible
- MEP recording immediately after the pulse
- Direct control from the DuoMAG software
- For motor-cortex mapping, MT (motor threshold)
SOFTWARE
Windows interface + dashboard
Touchscreen software for complete control — preset protocols (10 Hz, iTBS, cTBS, deep TMS), a custom-protocol creator, patient database, automatic per-session report, user management with access rights.
- Preset protocols (10 Hz, iTBS, cTBS)
- Custom protocol creator
- Patient database + per-session report
- User management + access rights
CONTROL ON COIL
Control buttons on the coil
Physical buttons on the coil handle for intensity adjustment / start-stop / marker — the operator does not need to return to the console during the session.
- Start / Stop directly on the coil
- Intensity adjustment on the handle
- Programmable event marker
- Reduces session interruption
TECHNICAL SPECIFICATIONS
DuoMAG XT / XTR operating parameters
| Models | 4 variants: XT-10, XT-35, XT-100, XTR |
|---|---|
| Pulse type | Biphasic (all 4 models) |
| Max repetition rate | 30 / 60 / 100 / 100 pps (XT-10 / XT-35 / XT-100 / XTR) |
| Modes | Single · Repetitive · Burst (Burst only on XT-35 / XT-100 / XTR) |
| Theta-Burst @ 100% | XTR — exclusive |
| Compatible coils | 15+ DEYMED models (butterfly, T-shaped, V-shaped, round) |
| Coil cooling | Air (Cool) or liquid (LQC) — optional on MagTower / MagCart |
| Synchronisation | TTL In/Out + USB Full Control · Control on Coil |
| Software | Windows touchscreen · preset + custom protocols · per-session report |
| Integrare | TruScan EEG (TMS-EEG) · TruTrace EMG (MEP) |
| Configurations | MagTower (counterbalanced arm) · MagCart (mobile) · Compact (desktop) |
| Power supply | 100–240 VAC, 50/60 Hz |
| Manufacturer | DEYMED Diagnostic (Czech Republic) |
| Compliance | Marcaj CE (MDR) |
CLINICAL & RESEARCH INDICATIONS
Where the DuoMAG XT makes the difference
-
Treatment-resistant depression
10 Hz rTMS protocols over the left DLPFC — therapy approved by FDA / CE for MDD. With XTR + iTBS, a 3-minute protocol (Cole et al. 2018).
-
Obsessive-compulsive disorder (OCD)
Deep TMS stimulation over the SMA / medial prefrontal cortex — V-shaped 90BFVT or 120BFVT coils for deep penetration.
-
Post-stroke recovery
rTMS for motor and aphasia rehabilitation after stroke — low-frequency protocols on the healthy hemisphere or high-frequency on the lesioned cortex.
-
Chronic pain (fibromyalgia, neuropathy)
rTMS over the M1 motor cortex for refractory chronic pain — 10 Hz protocols with 70BF-LQC, indicated in international guidelines.
-
Motor-cortex mapping (MEP)
With TMS-compatible TruTrace EMG — pre-surgical or research mapping, MT (motor threshold) calculation, screening with a 100R/125R round coil.
-
TMS-EEG / TMS-EMG research
With TruScan EEG (RE Plus, TMS-compatible) or TruTrace EMG — advanced studies of cortical excitability, SICI, LICI, synaptic plasticity (TBS).
WHY THE DuoMAG XT
One of the few rTMS devices with TBS at 100% intensity (XTR)
The most recent FDA-approved rTMS protocols (SAINT, Stanford 2022) use iTBS at 100% intensity. Very few rTMS devices on the market can deliver this protocol — XTR is one of them. Plus, the native integration with Deymed EEG / EMG / IONM makes DuoMAG the ideal solution for research centres + ambulatory TMS clinics.
- XTR — TBS at 100% intensity (rare on the market)
- 15+ compatible coils, including liquid cooling
- TruScan EEG + TruTrace EMG integration on the same cart
- Built in the Czech Republic — DEYMED Diagnostic (founded 1991)
- CE marked MDR · European technical support
Interested in the DuoMAG XT / XTR?
Hellimed provides technical consulting, clinical demonstrations, installation and training for the DuoMAG XT — for therapeutic rTMS practices (depression, OCD), neuro-rehabilitation departments and neurophysiology research laboratories (TMS-EEG, TMS-EMG). Tell us which variant you need (XT-10 / XT-35 / XT-100 for clinical use, XTR for premium research with TBS).
Request a quote for the DuoMAG XT