NEONATAL VENTILATOR — FROM 2 mL TIDAL VOLUME

bellavista® 1000 neo

The bellavista 1000 neo (ZOLL) is the newborn-optimised version of the bellavista platform — the only one with an internal turbine that supports tidal volumes from 2 mL. It combines invasive ventilation, NIV (nCPAP, nIPPV) and high-flow oxygen therapy in a single device, with the Infant Flow® LP interface anatomically optimised for premature infants.

Model: ZOLL bellavista 1000 neo

ZOLL bellavista 1000 neo neonatal ventilator
2 mLminimum tidal volume — premature infants
13,3″full-HD touchscreen
3-în-1invasive · NIV · HFOT
NICUturbine + Infant Flow® LP

NEONATAL OPTIMISATION

The same bellavista platform — fully adapted for the NICU

The bellavista 1000 neo keeps the internal-turbine architecture of the bellavista family (no external compressor, battery autonomy, HL7 connectivity) but adds the elements indispensable in neonatal intensive care: tidal volume from 2 mL, the nCPAP and nIPPV modes with the Infant Flow® LP interface, Burst Backup for apnea, and flow sensors with an extremely low dead space.

  • Tidal volume from 2 mL — adapted for extremely premature infants
  • Infant Flow® LP interface — minimal work of breathing
  • nCPAP + nIPPV with Burst Backup for apnea
  • Full invasive conventional modes
  • Integrated HFOT (Oxygen Therapy) — high-flow oxygen therapy
  • Internal turbine — no external compressor, transport-compatible

SMART FEATURES

Personalised for the smallest patient

The premature lung needs breaths of only a few millilitres, precise pressures and perfect synchronisation with the newborn's fragile effort. The bellavista 1000 neo brings the bellavista family's "auto" stack, adapted for the NICU.

Infant Flow® LP

The gold interface for neonatal CPAP

Infant Flow® LP (low pressure) is the interface developed anatomically for the newborn. It significantly reduces the work of breathing through the unique design of the flow generator — adapted to neonatal nasal dimensions and physiology.

  • Minimal work of breathing (WOB) for the premature infant
  • Compatible with nasal prongs and neonatal masks
  • Clinically validated specifically with the bellavista 1000 neo
  • Gold standard in NICUs worldwide

SYNCHRONISATION

auto.sync · auto.rise · auto.leak

The "auto" algorithm stack works breath by breath: it detects the expiratory threshold for optimal synchronisation with the newborn's effort, automatically adjusts the pressure rise time and compensates for NIV leaks — critical when working with nasal prongs.

  • auto.sync — synchronisation with the premature infant's fragile effort
  • auto.rise — adapted rise time (no overshoot)
  • auto.leak — neonatal NIV leak compensation
  • Reduces asynchrony and false alarms

HFOT

Integrated high-flow oxygen therapy

HFOT (High-Flow Oxygen Therapy) as a native mode — an alternative to nCPAP in mild-to-moderate respiratory distress. It allows a direct nCPAP → HFOT transition on the same device, as the newborn evolves clinically.

  • High flow with titrated O₂ 21–100%
  • Indicated post-extubation and for mild distress
  • Compatible with neonatal nasal cannulas
  • nCPAP ↔ HFOT transition on the same device

Burst Backup

Apnea of prematurity — automatic management

Burst Backup is the backup ventilation mode for neonatal apnea — it automatically activates synchronised breaths when an apnea episode is detected, then returns to nCPAP when the newborn resumes spontaneous effort. Essential in the NICU.

  • Automatic activation when apnea is detected
  • Returns to nCPAP when spontaneous effort resumes
  • Indicated in apnea of prematurity
  • Compatible with nCPAP mode

TECHNICAL SPECIFICATIONS

bellavista 1000 neo operating parameters

Target patientsNewborns (primary focus), including premature infants in the first week of life
Target tidal volumeFrom 2 mL upwards
Non-invasive modesnCPAP · nIPPV · NIV · HFOT
Invasive conventional modesPCV · PSV · SIMV · CMV (full bellavista range)
Interfața NIVInfant Flow® LP — anatomically validated for neonatology
Burst BackupIncluded — for apnea of prematurity
Automatic synchronisationauto.sync · auto.rise · auto.leak
HFOTIntegrated as a native mode
Display13.3″ full-HD touchscreen
Air sourceInternal turbine (no external compressor)
FiO₂21 – 100 %
ConnectivityHL7 · EMR / HIS · VueLink · IntelliBridge
ComplianceCE marked — built in Switzerland (imtmedical)

CLINICAL INDICATIONS

Where every millilitre counts

  • Respiratory distress syndrome (RDS)

    Early nCPAP with Infant Flow® LP — the evidence-based gold standard for managing RDS in premature infants.

  • Apnea of prematurity

    Burst Backup activates automatically when apnea is detected and returns to nCPAP when spontaneous effort resumes.

  • Post-extubation support

    Direct invasive → nCPAP → HFOT transition on the same device — reduces the need for re-intubation.

  • NICU

    Covers the full spectrum of neonatal ventilatory support — from the full-term newborn to the extremely premature infant.

  • Intra-hospital transport

    Internal turbine (no compressed air) + battery. Seamless switch from transport to the NICU incubator.

  • Infant bronchiolitis

    nCPAP or HFOT — an alternative to intubation in infants with severe bronchiolitis (RSV).

BELLAVISTA FAMILY COMPARISON

Which model to choose: neo, 1000 select or 1000e?

1000 neo1000 select1000e
PatientsNewborns (focus)Pediatric + adultNeonatal + pediatric + adult
Min. VT2 mL40 mL2 mL (cu Neonatal Suite)
Touchscreen13,3″13,3″17,3″ full-HD
Infant Flow® LPIncluded, anatomically validatedCompatible
Burst BackupIncludedIncluded
HFOTIncludedIncludedIncluded, native mode
Cloud RKPOptionalOptionalNatively integrated
FDA 510(k)Cleared (Nov. 2019)
Recommended forNICU dedicatAdult/pediatric ICU, NIVReference centres, all ages, cloud workflows

WHY THE bellavista 1000 neo

A perfect balance of specialisation and versatility

Unlike the bellavista 1000e (the flagship with a large touchscreen and all ages), the 1000 neo is 100% optimised for the NICU — the Infant Flow® LP interface, Burst Backup and tidal volume from 2 mL are clinically validated for the smallest patient. Compared with the bellavista 1000 select, it has all the neonatology-specific elements the 1000 select does not include.

  • The only bellavista platform with validated Infant Flow® LP
  • Tidal volume from 2 mL — extremely premature infants
  • Burst Backup for apnea of prematurity
  • Built in Switzerland (imtmedical, a ZOLL division)
  • Internal turbine — compatible with intra-hospital transport

Interested in the bellavista 1000 neo?

Hellimed provides technical consulting, clinical demonstrations and training for the bellavista 1000 neo — for dedicated NICU wards. We help you compare it with the fabian HFO, fabian nCPAP Evolution and bellavista 1000e to choose the right model for your needs.

Request a quote for the bellavista 1000 neo